Switching To The Backup Rom Through The Rom-Based Setup Utility - HP ML570 - ProLiant - G2 Setup And Installation Manual

Hp proliant ml570 generation 2 server setup and installation guide
Hide thumbs Also See for ML570 - ProLiant - G2:
Table of Contents

Advertisement

Server Configuration and Utilities
There are two methods of accessing the redundant ROM:
Switching to the backup ROM through RBSU
Manually forcing to the backup ROM through the system maintenance switch
(SW4)
Switching to the Backup ROM through the ROM-Based Setup
Utility
Use ROMPaq utilities to create a backup ROM image before upgrading the
configuration or to restore saved ROM data.
1. Access RBSU by pressing the F9 key during power up when the prompt displays
in the lower right corner of the screen.
2. Select Advanced Options.
3. Select ROM Selection.
4. Select one of the ROM banks as the system ROM.
5. Press the Enter key.
6. Press the Esc key to exit the current menu, or press the Esc key, then press the
F10 key at the prompt to exit RBSU.
7. Restart the server.
If both the current and backup versions of the ROM are corrupt, the server
automatically enters the ROMPaq disaster recovery mode. To perform this
procedure, refer to the "ROMPaq Disaster Recovery" section in Appendix E,
"Troubleshooting."
8-12
HP ProLiant ML570 Generation 2 Server Setup and Installation Guide