6. Locate and be sure that the rear LEDs on the hot-plug power supply are
activated.
Figure 3-46: Power supply LEDs (rack configuration)
Table 3-12: Power Supply LEDs
Power Supply Condition
No AC power to any power supply
No AC power to a particular power
supply
AC power present; system in standby
mode
Power supply on and working properly
Power supply current limit exceeded
7. Be sure that the external health LED on the front Power On/Standby button of the
system is illuminated green, indicating that the system is functioning properly.
For detailed information on LEDs, refer to Appendix C, "System LEDs and
Switches."
8. If any of the LEDs indicates an error, refer to Appendix D, "Troubleshooting," or
refer to the troubleshooting guide for instructions.
HP ProLiant ML570 Generation 2 Server Setup and Installation Guide
1: Power LED (Green)
Off
Off
Blinking
On
On
Installing Hardware Options
2: Fault LED (Amber)
Off
On
Off
Off
Blinking
3-53