CHAPTER 5 PICK-UP/FEEDING SYSTEM

3. Adjusting the Pressure on the Separation Pad

If double feeding or pick-up failure occurs during pick-up, change the position of the
separation pad:
If double feeding occurs, move the position of the spring holder
If pick-up failure occurs, move the position of the spring holder

4. Adjusting the Left/Right Registration

If the left-right registration is wrong when pick-up occurs in the multifeeder, loosen
the screws
, and adjust the position of the tray.