Self Diagnosis; Copier - Canon NP6330 Service Manual

Hide thumbs Also See for NP6330:
Table of Contents

Advertisement

VIII. SELF DIAGNOSIS
The microprocessor on the copier's DC controller is equipped with a function that
checks the condition of the copier (particularly, its sensors). The microprocessor runs a
check at such times as programmed and indicates an error code or executes error auto
power-off or error shut-off upon detection of an error.
A. Copier
Code
•Thermistor (TH1; off contact,
•Heater (H1, H2; open circuit)
•Thermal switch (TS1; open
E000
•SSR (faulty)
•DC controller PCB (faulty)
•Thermistor (TH1; short
•SSR (faulty)
E001
•DC controller PCB (faulty)
•Thermistor (TH1; poor
•Heater (H1, H2; open circuit)
•Thermal switch (TS1; open
•SSR (faulty)
•DC controller PCB (faulty)
E002
COPYRIGHT © 1997 CANON INC.
Cause
poor contact, open circuit)
circuit)
circuit)
contact, open circuit)
circuit)
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
Description
The temperature of the upper fixing
assembly does not reach 40°C within 27
sec after power-on.
(Notes 1, 2)
When an error associated with 'E000' is
detected, the copier turns off the power
switch in 2 sec and then turns off all
power supplies.
The temperature of the upper fixing
assembly exceeds 220°C.
(Notes 1, 2)
When an error associated with 'E001' is
detected, the copier turns off the power
switch in 2 sec and then turns off all
power supplies.
•The temperature does not reach 75°C
within 35 sec after reaching 40°C.
•The temperature does not reach 100°C
within 25 sec after reaching 75°C.
•The temperature does not reach 120°C
within 20 sec after reaching 100°C.
•The temperature does not reach 140°C
within 20 sec after reaching 120°C.
•The temperature does not reach 160°C
within 20 sec after reaching 140°C.
•The temperature does not reach 170°C
within 15 sec after reaching 160°C.
•The temperature does not reach 180°C
within 15 sec after reaching 170°C.
•The temperature does not reach 185°C
within 7 sec after reaching 180°C.
•The temperature does not reach 190°C
within 7 sec after reaching 185°C.
(Notes 1, 2)
When an error associated with 'E002' is
detected, the copier turns off the power
switch in 2 sec and then turns off all
power supplies.
11-179

Advertisement

Table of Contents
loading

Table of Contents