MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Initializing and Testing the System
Testing the System
Testing Outgoing Automatic-Start Tie Trunks
Perform this test for automatic-start tie trunks that are two-way or
outgoing only. If you are testing two-way automatic-start tie trunks,
perform the incoming test as well.
To test outgoing automatic-start tie trunks, follow the steps below:
At any telephone that has access to an automatic-start tie trunk,
press the first tie-trunk button.
The red LED next to the tie-trunk button just pressed turns on.
Pick up the handset. (In Hybrid/PBX systems with pooled tie trunks,
press an SA button and dial the pool dial-out code.)
The green LED next to the selected button turns on and you hear ringing.
When the person answers, verify that you have good two-way
communication and hang up.
The green LED should turn off, the red LED should turn off, and another
red LED may turn on.
Repeat Steps 1 through 3 for each outgoing and two-way
automatic-start tie trunk.
Testing Two-Way Dial-Repeating Tie Trunks
For two-way dial-repeating tie trunks, perform both the incoming and
outgoing dial-repeating tie trunk tests.
Testing Incoming Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or
incoming only. If you are testing two-way dial-repeating tie trunks,
perform the outgoing test as well.
To test incoming dial-repeating tie trunks, follow the steps below:
Issue 1
August 1998
Page 7-11