MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Connecting Data Equipment
Analog Voice and Modem Data Stations
Make sure that the modem has settings for speed and parity that
are compatible with those of the data terminal.
If you are not sure, see the customer's system manager or the
documentation packaged with the modem, data communications
software, and data terminal.
Connect the modem to the GPA.
a. Plug one end of a D4BU cord into the TEL/EQUIP jack on the
GPA.
b. Plug the other end into the modem as indicated in the modem's
documentation.
Connect the GPA to the analog multiline telephone.
a. Plug one end of a D8AC cord into the VT jack on the back of the
GPA.
b. Plug the other end into the OTHER jack on the bottom of the
telephone.
c. Slide the switch on the back of the GPA to Automatic or Basic.
See "GPA Settings" above for your options.
Use a D8W cord to connect the STATION jack on the BR-241-B1
bridging adapter to the LINE jack on the analog multiline telephone.
Use two D8W cords to connect the EVEN and ODD jacks on the
BR-241-B1 bridging adapter to the extension jacks indicated on
Form 2a, System Numbering: Extension Jacks.
Connect the EVEN jack on the bridging adapter to the extension jack
associated with the even-numbered extension, not the logical ID.
Connect all power cords to an AC outlet that is not controlled by a
wall switch.
Issue 1
August 1998
Page 6-6