MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Installing Telephones and Adjuncts
Installing Adjuncts
To connect an adjunct to an analog multiline telephone:
a. Connect a 4-pair cord to the OTHER jack on the telephone.
b. Connect the other end to the VT jack on a General Purpose
Adapter (GPA).
c. Connect the cord from the adjunct to the TEL/EQUIP jack on the
GPA.
d. Go to Step 7.
Refer to "General Purpose Adapter" below for additional
information.
Insert the other end of the adjunct cord directly into the port for the
logical ID on the 012 or 016 (T/R) module as indicated on the system
form. Go to Step 7.
Test the adjunct by dialing its associated extension.
General Purpose Adapter
A General Purpose Adapter (GPA) lets you connect a T/R device—such
as a single-line telephone or modem—to an analog multiline telephone.
The device must be touch-tone, not rotary.
NOTE:
The GPA is intended for answer-only service, unless the telephone has
direct access to a line. It does not have touch-tone receivers or pulse dial
detectors; therefore, the associated analog multiline telephone must dial
calls.
The GPA cannot be used with a MERLIN II System Display Console.
When the system forms indicate a GPA for installation of an adjunct, follow
the steps below.
Plug one end of a 4-pair adjunct D8AC cord into the VT jack on the
back of the GPA.
Plug the other end into the OTHER jack on the underside of the
analog multiline telephone.
Plug the cord from the adjunct into the TEL EQUIP jack on the GPA.
Issue 1