MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Installing the PC, CAT, or Printer
Connecting a PC to the Control Unit
jacks. Also make sure that the building wiring has been connected
so that the wall jacks in each location connect to each other.
You need the following hardware for this procedure:
355AF adapter
EIA crossover cable
Two Z3A2 Asynchronous Data Units (ADUs)
ADU crossover cable
400B2 power adapter
2012D transformer
BR1A-4P adapter and 102 connecting block or 103 connecting
block
248B adapter
8-position wall jacks
4-pair plug-ended cable
D8W cords
D6AP power cord
EIA-232-D cables
To connect a PC 50 ft. (15.2m) or more distant, follow the steps below.
See Figure 5–2.
Plug one end of a D8W cord into the ADMIN jack on the control unit.
Plug the other end of the D8W cord into a 355AF adapter.
Connect an EIA crossover cable to the 355AF adapter.
Connect one end of an EIA-232-D cable to the EIA crossover cable
and plug the other end into the 25-pin male connector on the Z3A2
ADU.
Issue 1
August 1998
Page 5-4