MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Installing the Control Unit
Installing the Modules
Labeling
After all modules have been installed, label all jacks using the
numbered labels provided with the feature module.
Line/trunk labels have green numbers on off-white background.
Telephone labels have blue numbers on off-white background.
See
Figure 2-12 on page 2-40
telephone jacks on each module, and label them as described next.
Label each line/trunk jack on the modules sequentially, 1 through
80. Begin with the module in slot 1, numbering from bottom to top
on each module and working from left to right across the carrier(s).
The 100D module has 24 numbers assigned to the line/trunk jack.
Label each telephone jack sequentially, 1 through 144. Begin with
the module in slot 1, numbering from bottom to top on each module
and working from left to right across the carrier(s).
!
CAUTION:
The 008 OPT module is assigned 12 logical IDs, and the last four
numbers are not assigned to jacks. For example, if the previous
module (on the left) is labeled with logical IDs 1 through 8, label the
008 OPT jacks with logical IDs 9 through 16. Skip numbers 17
through 20. When you label the next module (on the right), label the
first jack as logical ID 21.