MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Installing the Control Unit
Overview
Control Unit Requirements
Dimensions
— Basic carrier: 14 in. wide by 23 in. high by 12 in. deep
— Basic carrier and one expansion carrier: 25 in. wide by 23 in. high
by 12 in. deep
— Basic carrier and two expansion carriers: 37 in. wide by 23 in. high
by 12 in. deep
Location
— Within 5 ft. (152 cm) of an AC power outlet that is not
switch-controlled
— Within 25 ft. (762 cm) of the network interface, or use an
Off-Premises Range Extender (OPRE)
— Within 1000 cable ft. (305 m) of telephones, or use an OPRE (for
basic telephones)
!
CAUTION:
The AC outlet for the control unit cannot be switch-controlled.
Plugging the control unit into such an outlet invites accidental
disconnection of the system.
Hardware Preassembly Process
If an installation is to be preassembled, wired, programmed, and tested
on the new lightweight plastic backboard, see "Installing the Backboard."
Backboard Requirements
The backboard should be wide enough to accommodate the carrier and
up to two additional carriers, assuming that system growth is
anticipated. There should be enough room on each side of the control
unit for the necessary wiring fields.
Issue 1