Table C-11: Hot-Plug SCSI Hard Drive LED Combinations
Activity
Online
LED
LED
Off
Off
Off
On
On or
On
flashing
HP ProLiant ML530 Generation 2 Server Setup and Installation Guide
Fault
State
LED
On
OK to replace the drive online.
The drive has failed and has been placed offline.
Off
OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
Off
OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and being accessed.
System LEDs and Switches