1700 - 1799, Hard Drive Test Error Codes - Compaq 5500R - ProLiant - 256 MB RAM Maintenance And Service Manual

For use with pentium ii xeon and pentium iii xeon processor-based servers only
Hide thumbs Also See for 5500R - ProLiant - 256 MB RAM:
Table of Contents

Advertisement

1700 – 1799, Hard Drive Test Error Codes
The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive
controller boards, hard drive cabling, and system board functions. If the system uses a drive
array controller, see the section for Array Diagnostic Utility (ADU).
Error Code
1700-xx
1701-xx
1702-xx
1703-xx
1704-xx
1705-xx
1708-xx
1709-xx
1710-xx
1715-xx
1716-xx
1717-xx
1719-xx
1736-xx
1799-xx
Note: * Error Checking and Correcting
Hard Drive Test Error Codes
Description
Hard drive ID drive types test
failed.
Hard drive format test failed.
Hard drive read test failed.
Hard drive write/read/compare
test failed.
Hard drive random seek test
failed.
Hard drive controller test failed.
Hard drive format bad track test
failed.
Hard drive reset controller test
failed.
Hard drive park head test failed.
Hard drive head select test failed.
Hard drive conditional format test
failed.
Hard drive ECC* test failed.
Hard drive power mode test failed.
Drive Monitoring failed.
Invalid hard drive type failed.
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-12
Recommended Action
1.
Run the System Configuration Utility and verify the
drive type.
2.
Replace the hard drive signal and power cables
and retest.
3.
Replace the hard drive controller and retest.
4.
Replace the hard drive and retest.
5.
Replace the system board and retest.
Diagnostic Tools 3-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 5500Proliant 5500r

Table of Contents