5-2 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
System Unit
Dimensions
Height
Depth
Width
Weight with one power supply and no hard drive
Input Requirements
Rated Input Voltage
Rated Input Frequency
Input Power
Rated Input Current
Power Supply Output Power
Rated Steady-State Power
Maximum Peak Power
Temperature Range
Operating
Non-operating
Shipping
Relative Humidity (noncondensing)
Operating
Nonoperating
Maximum Wet Bulb Temperature
Acoustic Noise
Idle (fixed disk drives spinning)
Operating (random seeks to fixed disks)
Heat Dissipation
System Unit Specifications
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 5-1
U.S.
19 in
24.5 in
12 in
90 lb
Low range
100 to 120 V
50 to 60 Hz
780W @ 110 VAC/1100W @ 220 VAC
8 A
Low range
500 W
540 W
°
°
50
to 95
F
°
°
-20
to 140
F
°
°
-22
to 122
F
20% to 80%
5% to 90%
°
101.7
F
NPEL (BELS)
6.0
6.1
2594 BTU/h
Metric
48.3 cm
30.5 cm
62.2 cm
40.9 kg
High range
200 to 240 V
50 to 60 Hz
6 A
High range
750 W
780 W
°
°
10
to 35
C
°
°
-30
to 60
C
°
°
-30
to 60
C
20% to 80%
5% to 90%
°
38.7
C
Average SPL (dBA)
43
44
3754 BTU/h