Table 3-2
POST Error Messages
continued
Audible Beeps
Error Code
L=Long S=Short
1773-Primary Fixed
Disk Port Assignment
Conflict
1774-Slot x Drive
Array - Obsolete data
found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
1775-Slot x Drive
Array – ProLiant
Storage System Not
Responding SCSI
Port (y): Check
storage system
power switch and
cables. Turn the
system power off
while checking the
ProLiant power and
cable connections,
then turn the system
power back on to
retry.
1776-Drive Array -
SCSI Port
Termination Error
1777-Drive Array
External Drive
Subsystem Error
1778-Drive Array
resuming Automatic
Data Recovery
process
1779-Drive Array
Controller detects
replacement drives
1780-Disk 0 Failure
For use with Pentium II and Pentium III Xeon processor-based servers only
Probable Source of Problem
None
Fixed disk drive error.
None
SMART-2 Controller error.
None
Storage system problem.
None
External and internal SCSI drives
are both configured to Port 1.
None
Cooling fan failure, internal
temperature alert or open side
panel.
None
This message appears whenever
a controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
None
Intermittent drive failure and/or
possible loss of data.
None
Hard drive/format error.
Diagnostic Tools 3-15
Recommended Action
Run the System Configuration
Utility and correct.
Data found in Array Accelerator
is older than data found on
drives. Press F1 to discard the
older data in the Array
Accelerator and retain the
newer data on the drives.
Turn off power to system.
Check external ProLiant power
switch – external drives must all
be powered up before or at the
same time as the main system.
Check cables. If retry does not
help, try replacing the cable,
ProLiant firmware, ProLiant
backplane, or the Smart Array
Controller.
Reconfigure drives.
Inspect for cooling fan failure or
open side panel.
No action necessary.
If this message appears and
drive X has not been replaced,
this indicates an intermittent
drive failure. This message also
appears once immediately
following drive replacement
whenever data must be restored
from backup.
Run Diagnostics. Replace failed
assembly as indicated.