600 - 699, Diskette Drive Test Error Codes - Compaq 5500R - ProLiant - 256 MB RAM Maintenance And Service Manual

For use with pentium ii xeon and pentium iii xeon processor-based servers only
Hide thumbs Also See for 5500R - ProLiant - 256 MB RAM:
Table of Contents

Advertisement

3-26 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
600 – 699, Diskette Drive Test Error Codes
The 600 series of Diagnostic error codes identifies failures with diskette, diskette drive, or
system board functions.
Error Code
600-xx
601-xx
602-xx
603-xx
604-xx
605-xx
606-xx
607-xx
608-xx
609-xx
610-xx
694-xx
697-xx
698-xx
699-xx
Diskette Drive Test Error Codes
Description
Diskette ID drive types test failed.
Diskette format failed.
Diskette read test failed.
Diskette write/read/compute test
failed.
Diskette random seek test failed.
Diskette ID media failed.
Diskette speed test failed.
Diskette wrap test failed.
Diskette write protect test failed.
Diskette reset controller test
failed.
Diskette change line test failed.
Pin 34 is not cut on 360 KB
diskette drive.
Diskette type error.
Diskette drive speed not within
limits.
Diskette drive/media ID error.
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-8
Recommended Action
1.
Replace the diskette and retest.
2.
Check and/or replace the diskette power and
signal cables and retest.
3.
Replace the diskette drive and retest.
4.
Replace the system board and retest.
1.
Replace the media and retest.
2.
Run the Configuration utility and retest.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 5500Proliant 5500r

Table of Contents