Table 3-2
POST Error Messages
continued
Audible Beeps
Error Code
L=Long S=Short
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
1793-Drive Array -
Array Accelerator
Battery Depleted -
Data Lost
(Error message 1794
also displays.)
1794-Drive Array -
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
1795-Drive Array -
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
1796-Drive Array -
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
1797-Drive Array -
Array Accelerator
Read Error Occurred.
Data in Array
Accelerator has been
lost. Array
Accelerator is
disabled.
For use with Pentium II and Pentium III Xeon processor-based servers only
Probable Source of Problem
None
This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory.
Power was then restored within
eight to ten days, and the data in
the Array Accelerator was
flushed to the drive array.
None
This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory. Array
Accelerator batteries failed. Data
in Array Accelerator has been
lost.
None
This is a warning that the battery
charge is below 75%. Posted-
writes are disabled.
None
This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory.
The data stored in the Array
Accelerator does not correspond
to this drive array.
None
Array Accelerator is defective or
has been removed.
None
Hard parity error while reading
data from posted-writes
memory.
Diagnostic Tools 3-19
Recommended Action
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid data
remaining in the Array
Accelerator.
Power was not restored within
eight to ten days. Perform
orderly system shutdowns to
avoid data remaining in the
Array Accelerator.
Replace the Array Accelerator
board if batteries do not
recharge within 36 power-on
hours.
Match the Array Accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the Array
Accelerator.
1.
Check that the Array
Accelerator is properly
seated.
2.
Run the System
Configuration Utility to
reconfigure the Compaq
IDA-2 without the Array
Accelerator.
Enable Array Accelerator.
continued