Compaq 5500R - ProLiant - 256 MB RAM Maintenance And Service Manual page 120

For use with pentium ii xeon and pentium iii xeon processor-based servers only
Hide thumbs Also See for 5500R - ProLiant - 256 MB RAM:
Table of Contents

Advertisement

3-62 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
Table 3-26
ASR-2 IML or Critical Error Log Messages
Message
Caution: Temperature Exceeded
Diagnostic Error
Error Detected On Boot Up
Processor Prefailure
NMI - PCI Bus Parity Error
NMI - Expansion Board Error
NMI - Expansion Bus Master
Time-Out
NMI - Expansion Bus Slave
Time-Out
NMI - Fail-Safe Timer Expiration
Processor Exception
NMI - Processor Parity Error
Server Manager Failure
NMI - Software Generated
Interrupt Detected Error
Caution: Temperature Exceeded
Abnormal Program Termination
ASR-2 Test Event
NMI- Automatic Server
Recovery Timer Expiration
Required System Fan Failure
UPS A/C Line Failure Shutdown
or Battery Low
ASR-2 detected by ROM
continued
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
An error was detected by the Diagnostics Utility. See the specific error code
in this chapter for a detailed explanation.
The server detected an error during the Power-On Self-Test (POST).
A CPU has passed an internal corrected error threshold; excessive internal
ECC cache errors.
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error condition, resulting in a
server failure.
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
The indicated processor exception occurred.
The processor detected a data error, resulting in a server failure.
An error occurred with the Server Manager/R.
Software indicated a system error, resulting in a server failure.
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
The operating system has encountered an abnormal situation that has
caused a system failure.
The System Configuration Utility generated a test alert.
The operating system has received notice of an impending ASR-2 timer
expiration.
The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates if an auto-shutdown sequence has been
invoked or if the battery has been nearly depleted.
An ASR-2 activity has been detected and logged by the system ROM.