6000 - 6099, Compaq Nic Boards Test Error Codes; 6500 - 6599, Scsi Hard Drive Test Error Codes - Compaq ProLiant 8000 Maintenance And Service Manual

Proliant 8000 intel pentium iii xeon 700mhz servers
Hide thumbs Also See for ProLiant 8000:
Table of Contents

Advertisement

6000 – 6099, Compaq NIC Boards Test Error Codes
The 6000 series of diagnostic error codes identifies failures with 32-bit Dualspeed
NetFlex-2/Token Ring controllers.
Error Code
6000-xx
6001-xx
6002-xx
6014-xx
6016-xx
6028-xx
6029-xx
6089-xx
6090-xx
6091-xx
6092-xx
6500 – 6599, SCSI Hard Drive Test Error Codes
The 6500 series of diagnostic error codes identifies failures with SCSI hard drives, SCSI hard
drive controller boards, SCSI hard drive cabling, and system board functions. If the system uses
a drive array controller, see the section for Array Diagnostic Utility (ADU).
Error Code
6500-xx
6502-xx
6505-xx
6506-xx
6509-xx
6523-xx
6528-xx
Compaq Network Interface Board Test Error Codes
Description
Network card ID failed.
Network card setup failed.
Network card transmit failed.
Network card configuration failed.
Network card reset failed.
Network card internal failed.
Network card external failed.
Network card open failed.
Network card initialization failed.
Network card internal loopback failed.
Network card external loopback failed.
SCSI Hard Drive Test Error Codes
Description
SCSI disk ID drive types test failed.
SCSI disk unconditional format test
failed.
SCSI disk read test failed.
SCSI disk SA/media test failed.
SCSI disk erase tape test failed.
SCSI disk random read test failed.
Media load/unload test failed.
Diagnostics and Troubleshooting 3-41
Table 3-11
Recommended Action
The following steps apply to error codes 6000-xx
through 6092-xx.
1.
Check the controller installation in the EISA
slot.
2.
Check the interrupt type and number
setting.
3.
Check the media connection at the
controller and Multistation Access Unit
(MAU).
4.
Check the media speed (4/16) and type of
Unshielded Twisted Pair/Shielded Twisted
Pair (UTP/STP) settings.
5.
Check the MAU, cabling, or other network
components.
6.
Replace the controller.
Table 3-12
Recommended Action
The following steps apply to error codes 6500-xx
through 6528-xx.
1.
Run the System Configuration Utility and
verify the drive type.
2.
Run the System Configuration Utility and
verify the drive type.
3.
Replace the SCSI disk drive signal and
power cables and retest.
4.
Replace the SCSI controller and retest.
5.
Replace the SCSI disk drive and retest.
6.
Replace the system board and retest.

Advertisement