3-20 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1798-Drive Array -
Array Accelerator
Write Error Occurred.
Array Accelerator is
disabled.
1799-Drive Array -
Drive(s) Disabled due
to Array Accelerator
Data Loss.
Select "F1" to
continue with logical
drives disabled.
Select "F2" to accept
data loss and to re-
enable logical drives.
Beeps only: 2 Long
Beeps only: 2 Long +
2 Short
(Run System
Configuration Utility -
F10 key)
(RESUME - F1 key)
continued
Audible Beeps
L=Long S=Short
None
None
2L
2L, 2S
None
None
For use with Pentium II and Pentium III Xeon processor-based servers only
Probable Source of Problem
Hard parity error while writing
data to posted-writes memory.
Volume failed due to loss of data
in posted-writes memory.
No valid memory is present in
the system.
Power is cycled. Temperature too
hot. Processor fan either not
installed or not spinning.
A configuration error occurred
during POST.
As indicated to continue.
Recommended Action
Enable Array Accelerator.
Press F1 to continue with
logical drives disabled or F2 to
accept data loss and re-enable
logical drive.
Replace failed memory with
valid memory.
Check fans.
Press F10 to run System
Configuration Utility.
Press F1