Compaq 5500R - ProLiant - 256 MB RAM Maintenance And Service Manual page 100

For use with pentium ii xeon and pentium iii xeon processor-based servers only
Hide thumbs Also See for 5500R - ProLiant - 256 MB RAM:
Table of Contents

Advertisement

3-42 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
Table 3-21
ADU Diagnostic Messages
Message
Error occurred
reading RIS copy
from SCSI Port x
Drive ID x
FYI: Drive (bay) X
is non-Compaq
supplied
Identify
controller data
did not match
with NVRAM
Identify logical
drive data did
not match with
NVRAM
Insufficient
adapter
resources
Less than 75%
batteries at
sufficient voltage
Less than 75%
batteries at
sufficient
voltage. Battery
pack X below
reference
voltage.
Logical drive X
failed due to
cache error
continued
Description
An error occurred while ADU was
trying to read the RIS from this drive.
The installed drive was not supplied
by Compaq.
The identify controller data from the
array controller did not match the
information stored in nonvolatile
RAM. This could occur if new,
previously configured drives have
been placed in a system that has
also been previously configured. It
could also occur if the firmware on
the controller has been upgraded and
the System Configuration Utility was
not run.
The identify unit data from the array
controller did not match with the
information stored in nonvolatile
RAM. This could occur if new,
previously configured drives have
been placed in a system that has
also been previously configured.
The adapter does not have sufficient
resources to perform operations to
the array accelerator board. Drive
rebuild may be occurring.
Operation of array accelerator board
has been disabled due to less than
75% of battery packs being at
sufficient voltage level.
Battery pack on array accelerator is
below required voltage levels.
This logical drive failed due to a
catastrophic cache error.
For use with Pentium II and Pentium III Xeon processor-based servers only
Recommended Action
If there were multiple errors, this drive may
need to be replaced.
If problems exist with this drive, replace it with
a Compaq drive.
Check the identify controller data under the
Inspect Utility. If the firmware version field is the
only thing different between the controller and
nonvolatile RAM data, this is not a problem.
Otherwise, run the System Configuration Utility.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
Operate the system without the array
accelerator board until the drive rebuild
completes.
Allow sufficient time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Allow sufficient time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Replace the array accelerator board and
reconfigure using the Array Configuration Utility.
continued