Juniper PHYSICAL LAYER - CONFIGURATION GUIDE V11.1.X Configuration Manual page 81

Junose software for broadband services routers
Table of Contents

Advertisement

load-interval
mru
mtu
Example
host1(config-if)#invert data
Use the no version to disable the feature.
See invert data.
Use to set the time interval at which the router calculates bit and packet rate
counters.
Choose a multiple of 30 seconds, in the range 30–300 seconds.
Example
host1(config-if)#load-interval 90
Use the no version to restore the default value, 300 seconds.
See load-interval.
Use to configure the MRU size for the interface.
Specify a value in the range 4–9996 bytes.
Coordinate this value with the network administrator on the other end of the
line.
If you set this parameter to a different value for another protocol, such as IP, the
router uses the lower value. This could produce unexpected behavior in your
network.
Example
host1(config-if)#mru 1500
Use the no version to restore the default, 1600 bytes.
See mru.
Use to configure the MTU size for the interface.
Specify a value in the range 4–9996 bytes.
Coordinate this value with the network administrator on the other end of the
line.
If you set this parameter to a different value for another protocol, such as IP, the
router uses the lower value. This could produce unexpected behavior in your
network.
Example
host1(config-if)#mtu 1500
Chapter 2: Configuring T3 and E3 Interfaces
Configuration Tasks
59