A cOCx/STMx interface is identified by the slot/port format, where:
For information about installing line modules and I/O modules in ERX routers, see
ERX Hardware Guide, Chapter 4, Installing Modules.

References

For more information about MIB support for cOCx/STMx interfaces, consult the
following resources:
For more information about APS/MSP, consult the following resources:
slot Number of the slot in which the line module resides in the chassis. In
ERX7xx models, line module slots are numbered 2-6 (slots 0 and 1 are reserved
for SRP modules). In ERX14xx models, line module slots are numbered 0–5 and
8–13 (slots 6 and 7 are reserved for SRP modules). In an ERX310 router, line
module slots are numbered 1–2 (slot 0 is reserved for the SRP module).
port Number of the port on the I/O module
A cOC3/STM1 I/O module has four ports. Each port accepts one pair of SC-style
fiber connectors.
The cOC12/STM4 I/O module has one or two ports. On an I/O module that
supports two ports, one port is active (primary) and the other is redundant.
Cabling both ports provides a redundant path to the interface. If the active port
fails, the redundant port automatically becomes active. You can configure only
port 0 on a cOC12/STM4 I/O module. Port 0 accepts one pair of SC-style fiber
connectors.
On I/O modules that support APS/MSP, the port numbers for the working
(primary) interfaces are assigned the lower half of the numbered interfaces,
whereas the port numbers for the protect (redundant) interfaces are assigned
the upper half of the numbered interfaces. For example, on an I/O module that
provides one primary port and one redundant port, the working interface is port
0 and the protect interface is port 1.
APS/MSP channel number Identifier of the working or protect interface for
configuration purposes
The protect interface is always assigned channel number 0. The working interface
is always assigned channel number 1.
RFC 1661 The Point-to-Point Protocol (PPP) (July 1994)
RFC 2495 Definitions of Managed Objects for the DS1, E1, DS2 and E2 Interface
Types (January 1999)
RFC 2496 Definitions of Managed Objects for the DS3/E3 Interface Types