Monitoring Interfaces
Severely errored frame seconds Number of severely errored framing
seconds encountered by a T3 or E3 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T3
or E3 in the current interval
Line code violations Number of line code violations encountered by a T3
or E3 in the current interval
P-bit coding violations Number of coding violations encountered by a T3
(not applicable for E3) in the current interval (this field is not present for E3
controllers)
Coding violations Number of coding violations encountered by an E3 (not
applicable for T3) in the current interval (this field is not present for T3
controllers)
Line errored seconds Number of line errored seconds encountered by a
T3 or E3 in the current interval
C-bit coding violations Number of C-bit coding violations encountered by
a T3 (not applicable for E3) in the current interval (this field is not present
for E3 controllers)
C-bit errored seconds Number of C-bit errored seconds encountered by a
T3 (not applicable for E3) in the current interval (this field is not present for
E3 controllers)
C-bit severely errored seconds Number of C-bit severely errored seconds
encountered by a T3 (not applicable for E3) in the current interval (this field
is not present for E3 controllers)
Example 1
host1#show controllers t3 2/0
DS3 2/0
Description: boston09 hdlc channel
ifAdminStatus = ifAdminDown
snmp trap link-status = enabled
No alarms detected
Framing is C-BIT, Line Code is B3ZS, Clock Source is Line
Cable Length is 0 ft
Loopback Disabled
DSU Mode is Larscom
DSU Bandwidth is 4000
DSU Scrambler is off
MDL Transmit Path is not active
MDL Transmit Test-Signal is active
MDL Transmit Idle-Signal is not active
Equipment Identification Code is ERX-1400
Line Identification Code is Bldg 10
Frame Identification Code is null string
Unit Identification Code is 080001
Facility Identification Code is Site 25
Port Code is Port 0800
Generator Number is null string