Juniper PHYSICAL LAYER - CONFIGURATION GUIDE V11.1.X Configuration Manual page 62

Junose software for broadband services routers
Table of Contents

Advertisement

JUNOSe 11.1.x Physical Layer Configuration Guide
40
Monitoring Interfaces
DS1 Identifier of T1 channel
Number of valid intervals Number of 15-minute intervals since the line
module was last powered on or reset
Time elapse in current interval Number of seconds that have passed in the
15-minute (900-second) interval
Far End FDL Carrier bit Status of FDL configuration on remote device
connected to T1 channel
set FDL is configured for carrier mode
not set FDL is not configured for carrier mode
Far End Equipment Identification Code eic string sent by remote device
for FDL
Far End Line Identification Code lic string sent by remote device for FDL
Far End Frame Identification Code fic string sent by remote device for FDL
Far End Unit Identification Code unit string sent by remote device for FDL
Far End Facility Identification Code pfi string sent by remote device for
FDL
Far End Generator Number generator string sent by remote device for FDL
Far End Port Number port string sent by remote device for FDL
Errored seconds Number of errored seconds encountered by a T1 in the
current interval
Severely errored seconds Number of severely errored seconds encountered
by a T1 in the current interval
Severely errored frame seconds Number of severely errored framing
seconds encountered by a T1 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T1
in the current interval
Clock slip seconds Number of clock slips encountered by a T1 in the current
interval
Path code violations Number of coding violations encountered by a T1 in
the current interval
Line errored seconds Number of line errored seconds encountered by a
T1 in the current interval
Bursty errored seconds Number of bursty errored seconds encountered by
a T1 in the current interval
Degraded minutes Number of minutes that a T1 line is degraded
Example In this example, a T1 channel is specified.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E series

Table of Contents