JUNOSe 11.1.x Physical Layer Configuration Guide
36
Monitoring Interfaces
Equipment Identification Code is the null string
Line Identification Code is the null string
Frame Identification Code is the null string
Unit Identification Code is the null string
Facility Identification Code is the null string
Port Code is the null string
Generator Number is the null string
BERT test - 2 in 23
Test Interval 1 minute(s), Complete
Sync count = 1
Received bit count = 92148912
Error bit count = 17
Number of valid interval - 90
Time elapse in current interval - 580
Example 2 In this example, the brief keyword is specified for all T1 channels.
host1#show controllers t1 brief
Interfaces
5/0:1(framed)
5/0:2(framed)
5/0:3(framed)
5/0:4(framed)
5/0:5(framed)
5/0:6(framed)
...
5/2:26(framed)
5/2:27(framed)
5/2:28(framed)
Example 3 In this example, a T1 channel is specified.
host1#show controllers t1 1/0:1
DS1 1/0:1
Description: toronto t1 channel
ifOperStatus = ifOperUp
Yellow Alarm detection is active
Yellow Alarm generation is active
snmp trap link-status = disabled
Framing is D4, Line Code is Ami, Clock Source is Internal - Module
Allocated Ds0 time slot map = 0x0
Last Remote Loopback Request Sent - Deactivate
FDL is not configured
FDL Transmit Path-Id is not active
FDL Transmit Test-Signal is not active
FDL Transmit Idle-Signal is not active
Equipment Identification Code is the null string
Line Identification Code is the null string
Frame Identification Code is the null string
Unit Identification Code is the null string
Facility Identification Code is the null string
Port Code is the null string
Generator Number is the null string
BERT test - 2 in 23
Test Interval 1 minute(s), Complete
Sync count = 1
Received bit count = 92148912
Error bit count = 17
ifAdminStatus
OperationalStatus
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
up
lowerLayerDown
Need help?