Far End Equipment Identification Code eic string sent by remote device
for FDL
Far End Line Identification Code lic string sent by remote device for FDL
Far End Frame Identification Code fic string sent by remote device for FDL
Far End Unit Identification Code unit string sent by remote device for FDL
Far End Facility Identification Code pfi string sent by remote device for
FDL
Far End Generator Number generator string sent by remote device for FDL
Far End Port Number port string sent by remote device for FDL
Errored seconds Number of errored seconds encountered by a T1 in the
current interval
Severely errored seconds Number of severely errored seconds encountered
by a T1 in the current interval
Severely errored frame seconds Number of severely errored framing
seconds encountered by a T1 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T1
in the current interval
Clock slip seconds Number of clock slips encountered by a T1 in the current
interval
Path code violations Number of coding violations encountered by a T1 in
the current interval
number of coding violations encountered by a T1 in the current interval
Line errored seconds Number of line errored seconds encountered by a
T1 in the current interval
Bursty errored seconds Number of bursty errored seconds encountered by
a T1 in the current interval
Degraded minutes Number of minutes that a T1 line is degraded
Example 1 In this example, a T3 interface is specified.
host1#show controllers sonet 5/0:1/1 remote
Far End MDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Generator Number is the null string
Far End Port Number is the null string
Number of valid interval - 3
Time elapse in current interval - 756
Chapter 4: Configuring Channelized OCx/STMx Interfaces
Monitoring Interfaces
169