JUNOSe 11.1.x Physical Layer Configuration Guide
160
Monitoring Interfaces
Test interval Length of the BERT test
status Sync (controller is synchronized with remote device) or NoSync
(controller is not synchronized with remote device
Sync count Number of times the pattern detector synchronized with
the incoming data pattern
Received bit count Number of bits received
Error bit count Number of bits with errors
Number of valid intervals Number of 15-minute intervals since the line
module was last powered on or reset
Time elapsed in current interval Reported in 15-minute intervals
Errored seconds Number of errored seconds encountered by a T1 or an
E1 in the current interval
Severely errored seconds Number of severely errored seconds encountered
by a T1 or an E1 in the current interval
Severely errored frame seconds Number of severely errored framing
seconds encountered by a T1 or an E1 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T1
or an E1 in the current interval
Clock slip seconds Number of clock slips encountered by a T1 or an E1 in
the current interval
Path code violations Number of coding violations encountered by a T1 or
an E1 in the current interval
Line errored seconds Number of line errored seconds encountered by a
T1 or an E1 in the current interval
Bursty errored seconds Number of bursty errored seconds encountered by
a T1 or an E1 in the current interval
Degraded minutes Number of minutes that a T1 or an E1 line is degraded
Line code violations Number of line code violations encountered by a T1
or an E1 in the current interval
Example This example displays statistics for all the E1 lines on the interface
2/0.
host1#show controllers sonet 2/0 e1
E1 1/1/1
Description: boston111 e1
BERT test - 2 in 11
Test Interval 1 minute(s), Running - Status is Sync
0 minute(s), 33 second(s) left in test interval
Sync count
= 1

Advertisement