Juniper JUNOSE 11.2.X PHYSICAL LAYER Configuration Manual page 89

For e series broadband services routers - physical layer configuration
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
P-bit errored seconds—Number of errored seconds encountered by a T3 (not
applicable for E3) in the current interval (this field is not present for E3 controllers)
Severely errored seconds—Number of severely errored seconds encountered by an
E3 (not applicable for T3) in the current interval (this field is not present for T3
controllers)
P-bit severely errored seconds—Number of severely errored seconds encountered
by a T3 (not applicable for E3) in the current interval (this field is not present for E3
controllers)
Severely errored frame seconds—Number of severely errored framing seconds
encountered by a T3 or E3 in the current interval
Unavailable seconds—Number of unavailable seconds encountered by a T3 or E3
in the current interval
Line code violations—Number of line code violations encountered by a T3 or E3 in
the current interval
P-bit coding violations—Number of coding violations encountered by a T3 (not
applicable for E3) in the current interval (this field is not present for E3 controllers)
Coding violations—Number of coding violations encountered by an E3 (not applicable
for T3) in the current interval (this field is not present for T3 controllers)
Line errored seconds—Number of line errored seconds encountered by a T3 or E3 in
the current interval
C-bit coding violations—Number of C-bit coding violations encountered by a T3 (not
applicable for E3) in the current interval (this field is not present for E3 controllers)
C-bit errored seconds—Number of C-bit errored seconds encountered by a T3 (not
applicable for E3) in the current interval (this field is not present for E3 controllers)
C-bit severely errored seconds—Number of C-bit severely errored seconds
encountered by a T3 (not applicable for E3) in the current interval (this field is not
present for E3 controllers)
Example 1
host1#show controllers t3 2/0
DS3 2/0
Description: boston09 hdlc channel
ifAdminStatus = ifAdminDown
snmp trap link-status = enabled
No alarms detected
Framing is C-BIT, Line Code is B3ZS, Clock Source is Line
Cable Length is 0 ft
Loopback Disabled
DSU Mode is Larscom
DSU Bandwidth is 4000
DSU Scrambler is off
MDL Transmit Path is not active
MDL Transmit Test-Signal is active
Chapter 2: Configuring T3 and E3 Interfaces