Juniper JUNOSE 11.2.X PHYSICAL LAYER Configuration Manual page 53

For e series broadband services routers - physical layer configuration
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
Test interval—Length of the BERT test
status—Sync (controller is synchronized with remote device) or NoSync (controller
is not synchronized with remote device)
Sync count—Number of times the pattern detector synchronized with the incoming
data pattern
Received bit count—Number of bits received
Error bit count—Number of bits with errors
Number of valid intervals—Number of 15-minute intervals since the line module was
last powered on or reset
Time elapse in current interval—Reported in 15-second intervals
P-bit errored seconds—Number of errored seconds encountered by a T3 in the current
interval
P-bit severely errored seconds—Number of severely errored seconds encountered
by a T3 in the current interval
Severely errored frame seconds—Number of severely errored framing seconds
encountered by a T3 in the current interval
Unavailable seconds—Number of unavailable seconds encountered by a T3 in the
current interval
Line code violations—Number of line code violations encountered by a T3 in the
current interval
P-bit coding violations—Number of coding violations encountered by a T3 in the
current interval
Line errored seconds—Number of line errored seconds encountered by a T3 in the
current interval
C-bit coding violations—Number of C-bit coding violations encountered by a T3 in
the current interval
C-bit errored seconds—Number of C-bit errored seconds encountered by a T3 in the
current interval
C-bit severely errored seconds—Number of C-bit severely errored seconds
encountered by a T3 in the current interval
Example 1—In this example, a T3 interface is specified.
host1#show controllers t3 2/0
DS3 2/0
Description: toronto ct3 interface
ifAdminStatus = ifAdminDown
snmp trap link-status = enabled
No alarms detected
Chapter 1: Configuring Channelized T3 Interfaces
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.2.x

Table of Contents