On EX4500 switches, if you activate and then deactivate a firewall filter configuration,
VSTP convergence might not occur properly. As a workaround, restart the Ethernet
switching process (
eswd
On an interface that is receiving storm traffic, if you use the
ethernet-switching-options storm-control action-shutdown
interface, it can take up to 30 seconds for the interface to shut down. [PR/556107]

Firewall Filters

On EX4200 switches, if you configure a firewall filter with the match condition
, the error message "not supported" is displayed. [PR/543316]
tcp-established

Hardware

On EX4200 switches, the uplink port status LED on the 4-port Gigabit Ethernet SFP
does not properly indicate the status of the uplink port. [PR/528070]
If no Intraconnect module or Virtual Chassis module is installed in EX4500 switches,
the switch boots but is not fully functional. Traffic loss can occur during packet
forwarding. [PR/544628]

Infrastructure

On EX8200 switches, when IGMP snooping is enabled on an interface, the IPv6
multicast Layer 2 control frame is not forwarded to other interfaces in the same VLAN.
The result is that IPv6 and VRRP for IPv6 neighbor solicitation fails. [PR/456700]
On EX8200 switches, when you perform a graceful Routing Engine switchover (GRES)
or when you restart Ethernet switching on any spanning-tree protocol domain, a loop
might occur. [PR/516611]
On EX8200 switches, if a
action in a firewall filter configuration, logging does not work. [PR/540097]
On EX8200 switches, the LACP process (
traffic to the Routing Engine is heavy. [PR/542897]
On EX4200 switches, the SFP+ uplink module might not work correctly even though
the link status is UP. [PR/569307]
On EX4500 switches, if more than 14 ports in the switch are subscribed to a 10-gigabit
full-duplex rate of traffic, the switch might not be able to achieve a 10-gigabit wire rate
for 64 and 128 byte packets. There is no impact on performance if the number of ports
actively involved in 10-gigabit wire-rate traffic is 14 or fewer or if the packet size is
greater than 150 bytes. [PR/573319]
If you set a custom chassis display message with the
command, the message might remain on the LCD panel indefinitely even
message
though you did not include the
On EX8200 switches, when you are upgrading the line cards, the nonstop software
upgrade (NSSU) process might abort. The system generates a core file when this
happens. [PR/580494]
Outstanding Issues in Junos OS Release 10.4 for EX Series Switches
). [PR/548446]
or a
action is configured along with an
log
syslog
lacpd
) might start and stop repeatedly when
permanent
option in your command. [PR/579234]
set
command to disable the
interface
set chassis display message
203