Juniper JUNOS OS 10.4 - RELEASE NOTES REV 6 Release Note page 56

Hide thumbs Also See for JUNOS OS 10.4 - RELEASE NOTES REV 6:
Table of Contents

Advertisement

JUNOS OS 10.4 Release Notes
56
Discrepancies exist in MAC and filter statistics between Trio MPC and Enhanced DPCs.
[PR/517926]
The
multipoint-destination
the configuration of this statement is accepted without problems initially, subsequent
reconfiguration of the interface might cause the FPC and Packet Forwarding Engine
to reboot. [PR/529423]
When a configuration contains a large number of logical interfaces, and graceful Routing
Engine switchover is not configured, the
in some of the FPCs staying offline. As a workaround, enable graceful Routing Engine
switchover (
set chassis redundancy graceful-switchover
When the
show interfaces
is displayed. This information is visible under the interfaces hierarchy (configuration).
[PR/541574]
On a 20-port Gigabit Ethernet Enhanced Queuing IP Services DPC and a 2-port
10-Gigabit Ethernet Enhanced DPC, the link status of the interface goes down when
the TX router towards the peer is removed. [PR/542668]
On MX Series routers, the following syslog error messages appear when a configuration
change is made and committed:
UI_DBASE_LOGIN_EVENT: User 'regress' entering configuration mode
UI_COMMIT: User 'regress' requested 'commit synchronize' operation
(comment: none)
Shared memory release
vccpd_platform_get_serial_num: read s/n JN10C843EAFA success, task_state
5123
vcdb_extract_db_from_file reading file /config/vchassis/vc.tlv.db
vcdb_extract_db_from_file Error opening file. errno = 2
vcdb_extract_db_from_file reading file /config/vchassis/vc.db
vcdb_extract_db_from_file: DB Files couldn't be read.
vccpd_platform_get_serial_num: read s/n JN10C843EAFA success, task_state
7171
Shared memory release
sysctl_nd6_mmaxtries: 3, max solicit testing setting of
paramsysctl_nd6_mmaxtries: 3, max solicit testing setting of
paramsysctl_nd6_mmaxtries: 3, max solicit testing setting of
paramsysctl_nd6_mmaxtries: 3, max solicit testing setting of
paramsysctl_nd6_mmaxtries: 3, max solicit testing setting of
paramsysctl_nd6_prune: 1, retrans timer testing setting of
paramsysctl_nd6_prune: 1, retrans timer testing setting of
paramsysctl_nd6_prune: 1, retrans timer testing setting of
paramsysctl_nd6_prune: 1, retrans timer testing setting of
paramsysctl_nd6_prune: 1, retrans timer testing setting of param
[PR/548853]
After an MX80 router is upgraded to Junos OS Release 10.3, the "Front Panel Alarm
Indicators" LEDs do not show any status in the output of the
command, even when there is chassis alarm set on the router. [PR/558046]
Under certain conditions, both the primary and the secondary sections of the interface
might get disabled. To recover from this condition, deactivate and activate the interface
configuration. [PR/559656]
configuration statement is not supported on IQE PICs. While
restart chassis-control
command is used, no service set attachment information
command might result
). [PR/532030]
show chassis craft-interface
Copyright © 2011, Juniper Networks, Inc.