66
If the
always-compare-med
protocol process might occasionally crash due to a soft assertion. However, the soft
assertion does not impact the user traffic. [PR/568725: This issue has been resolved.]
During a nonstop active routing (NSR) switchover with a large number of remote Layer
3 VPN prefixes, and a local eBGP session with short hold timers, routing protocol
process scheduler slips might occur, which causes the BGP session to flap. [PR/568756:
This issue has been resolved.]
Under certain circumstances, processing of links with maximum metric set by IS-IS
shortest path first (SPF) computation algorithm might lead to suboptimal routing
decisions. [PR/569649: This issue has been resolved.]
Services Applications
In scaled environments, the thread in the Multiservices PIC or DPC for cflow might run
too long. This causes the PIC or DPC to crash. [PR/494457: This issue has been
resolved.]
On Multiservices 500 PICs with graceful Routing Engine switchover, wrong record
values are seen for the IPv4 netflow export packets. This error occurs when the route
records does not get installed. [PR/545422: This issue has been resolved.]
The Multiservice 400 PIC crashes due to a memory allocation failure when the PIC
tries to respond to a Routing Engine CLI request. [PR/558237: This issue has been
resolved.]
The Multiservices PIC might crash when traffic is received on a Layer 2 Tunneling
Protocol (L2TP) session (MLPPP bundle), and a teardown request is also received at
the same time. [PR/561039: This issue has been resolved.]
If Bidirectional Forwarding Detection protocol (BFD) protection for BGP sessions is
configured on a BGP session in a nonmaster routing instance, the BFD might start for
that session before the kernel ID of the routing instance is set. This might cause the
BFD session to freeze. As a workaround, if the BFD session has the routing table value
of 4294967295, use the
address the issue as long as the routing instance's kernel table is allocated. [PR/563161:
This issue has been resolved.]
If a class-of-service rule is applied to a service set, the inactive timeout under the
user-configured application does not take effect. As a workaround, match the
application in the class-of-service rule. [PR/571304: This issue has been resolved.]
User Interface and Configuration
Under certain circumstances, a nested Junos OS configuration group with a wildcard
match might not have the desired effect. [PR/556379: This issue has been resolved.]
When a "validate" RPC is executed using a NETCONF session, some essential
information about the session is not populated in the configuration database.
[PR/570778: This issue has been resolved.]
VPNs
In MVPN routing-instances with local receivers, a flood next hop is created for each
S,G entry for multicast traffic received from the CE. After the local receivers are joined
option is configured when a route change occurs, the routing