Correlating Hard Drive Slots To Raidstatus Command Physical Port Numbers - Cisco CS-MARS-20-K9 - Security MARS 20 User Manual

Security mars local controller
Table of Contents

Advertisement

Hardware Maintenance Tasks—MARS 100, 100E, 200, GCM, and GC
Table 24-1
Output Field
# OF PORTS: 8
PORT 0: WDC WD2500JB-19GVA0 WD-WCAL73129135
232.88 GB (488397168 BLOCKS)
: OK(UNIT 0)
SUBUNIT 1:
SUBUNIT 0:
PHYSICAL PORT: 6
LOGICAL
SUBUNIT 1:
PHYSICAL PORT: 3
LOGICAL

Correlating Hard Drive Slots to RAIDSTATUS Command Physical Port Numbers

This section pertains only to the MARS 100, 100E, 200, GCM, and GC appliances.
Figure 24-4
drive slot numbers increase from left to right, and from top to bottom.
for the Local Controller 100 and 100E.
The MARS CLI identifies hard drives by port numbers or physical port numbers, which are logical
designations assigned by the operating system.
correspond to the port and physical port numbers as reported in the CLI.
User Guide for Cisco Security MARS Local Controller
24-16
Explanation of Output Fields for raidstatus CLI Command (continued)
RAID 1: REBUILDING (1%)
CBOD: DEGRADED
PORT: 0
CBOD: OK
PORT: 1
shows how the hard drive slot numbers are ordered in MARS LC-200, GC, or GCM. Hard
Description
Indicates the number of hard drives in the array.
Indicates the model, serial number, size, and
operational status of a hard drive related to the
port. If a hard drive is not present or cannot be
accessed, this output does not appear for that port.
Table 24-2
lists how hard drive bays map to the
port numbers.
A MARS RAID 10 configuration comprises
multiple RAID 1 subunits, each RAID 1 subunit
configured with two drives. The MARS 100 and
100e appliances have subunits numbered 0,1, and
2. MARS 200 appliances and Global Controllers
have subunits 0,1,2, and 3.
The two drives in each RAID 1 subunits have
unique physical port numbers.
The RAID 1 subunit status values are as follows:
OK—The subunit is in good order and
operating at optimal efficiency.
Rebuilding—The subunit is being rebuilt,
efficiency is not yet optimal.
Degraded—At least one physical disk in the
array cannot be accessed.
The rebuild processes can take between 90
minutes and two hours to complete, depending on
the amount of data on the disk. Subunits are
rebuilt one subunit at a time. The percentage
complete indicator tells you which subunit is
currently being rebuilt.
The Physical Port number appears as N/A when
the associated drive bay is empty.
Individual drive status is shown in the CBOD:
field. CDBOD status can be OK or DEGRADED.
Figure 24-5
Table 24-2
shows how the hard drive slots in the chassis
Chapter 24
System Maintenance
shows slot numbering
78-17020-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mars 20Mars 50Mars 100Mars 200

Table of Contents