Cisco CS-MARS-20-K9 - Security MARS 20 User Manual page 504

Security mars local controller
Table of Contents

Advertisement

Hardware Maintenance Tasks—MARS 100, 100E, 200, GCM, and GC
Tip
Press Y to confirm. MARS exits the RAID utility and resumes the bootup process.
Step 6
At the CLI prompt, verify with the raidstatus command that the RAID array subunit is rebuilding.
Step 7
If the subunit does not rebuild within two hours, delete the array and add the replacement drive with the
RAID utility as described in the section
This ends the
Add a Replacement Drive to the Array with the RAID Utility
This section pertains only to the MARS 100, 100E, 200, GCM, and GC appliances.
Perform this procedure when a hotswap attempt and the RAID Utility Rebuild procedure have failed.
Step 1
Insert the replacement drive into the hard drive slot.
Establish a direct console connection to MARS with a keyboard and an external monitor.
Step 2
Note
Reboot the MARS Appliance. Press Alt-3 to access the RAID utility when the following message
Step 3
appears:
*** <Press Alt-3 to access 3ware Configuration Screen ***>
The 3ware Disk Array Configuration utility (RAID Utility) home screen appears.
Read the help bar at the bottom of the screen for instructions on how to use the RAID Utility interface.
Step 4
Select Array Unit 0—position the cursor over the text and press Enter.
Step 5
A selected item is marked with an asterisk in the leftmost column.
Step 6
Select Delete Array, and press Enter.
A screen appears listing the ports and the hard drives of the array that will be deleted.
Tip
User Guide for Cisco Security MARS Local Controller
24-22
Within the RAID utility, you can use the following keystrokes to highlight the corresponding
GUI button:
Alt-C—Create Array
Alt-D—Delete Array
Alt-M—Maintain Array
Alt-R—Rebuild Array
Rebuilding an Array with the RAID Utility
You can access the RAID Utility only with a direct console connection.
Within the RAID utility, you can use the following keystrokes to highlight the corresponding
GUI button:
Alt-C—Create Array
Alt-D—Delete Array
Alt-M—Maintain Array
Alt-R—Rebuild Array
"Add a Replacement Drive to the Array with the RAID
procedure.
Chapter 24
System Maintenance
Utility."