Rmon Alarm Information; Rmon Event Information - HP GbE2c - Blc Layer 2/3 Fiber SFP Option Command Reference Manual

Hp gbe2c ethernet blade switch for c-class bladesystem command reference guide
Hide thumbs Also See for GbE2c - Blc Layer 2/3 Fiber SFP Option:
Table of Contents

Advertisement

RMON alarm information

Command: /info/rmon/alarm
RMON Alarm group configuration:
Index
-----
1
2
3
4
5
8
10
11
15
18
100
Index
-----
1
2
3
4
5
8
10
11
15
18
100
The following table describes the RMON Alarm Information parameters.
Table 42
RMON Alarm Information Menu /info/rmon/alarm
Command
Index
Interval
Type
rLimit
fLimit
rEvtIdx
fEvtIdx
Last value
OID

RMON event information

Command: /info/rmon/event
Interval
Type
rLimit
--------
----
--------
30
abs
900
abs
300
abs
1800
abs
1800
abs
1800
abs
1800
abs
1800
abs
1800
abs
1800
abs
1800
abs
OID
------------------------------
1.3.6.1.2.1.2.2.1.10.257
1.3.6.1.2.1.2.2.1.11.258
1.3.6.1.2.1.2.2.1.12.259
1.3.6.1.2.1.2.2.1.13.260
1.3.6.1.2.1.2.2.1.14.261
1.3.6.1.2.1.2.2.1.10.280
1.3.6.1.2.1.2.2.1.15.262
1.3.6.1.2.1.2.2.1.16.263
1.3.6.1.2.1.2.2.1.19.266
1.3.6.1.2.1.2.2.1.10.279
1.3.6.1.2.1.2.2.1.17.264
Displays the index number that identifies each alarm instance.
Displays the time interval over which data is sampled and compared with the rising and falling
thresholds.
Displays the method of sampling the selected variable and calculating the value to be compared
against the thresholds, as follows:
abs: absolute value, the value of the selected variable is compared directly with the thresholds at
the end of the sampling interval.
delta: delta value, the value of the selected variable at the last sample is subtracted from the current
value, and the difference compared with the thresholds.
Displays the rising threshold for the sampled statistic.
Displays the falling threshold for the sampled statistic.
Displays the rising alarm event index that is triggered when a rising threshold is crossed.
Displays the falling alarm event index that is triggered when a falling threshold is crossed.
Displays the last sampled value.
Displays the MIB Object Identifier for each alarm index.
fLimit
rEvtIdx
--------
-------
10
0
0
10
10
20
10
0
10
0
10
0
10
0
10
0
10
0
10
0
10
0
fEvtIdx
last value
-------
----------
1
0
0
2
0
0
1
0
1
0
1
0
56344540
1
0
1
0
1
0
1
0
1
0
Information Menu 56
0
0
0
0
0
0
0
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gbe2cXw460c - proliant - blade workstation

Table of Contents