5.2.
Environmental conditions
DLT-V72 without integrated UPS
Operating temperature
Storage temperature
Relative humidity
Mechanical vibration
and shock resistance
IP protection class
DLT-V72 with integrated UPS (optional)
Operating temperature
Storage temperature
Charging temperature
Relative humidity
Mechanical vibration
and shock resistance
IP protection class
DLT-V72 Series User Manual V2.76
-30 to +50 °C
Specification according to EN 60068-2-1/2
-30 to +65 °C
Specification according to EN 60068-2-1/2
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP65 and IP66 for:
DLT-V7210
DLT-V7212
DLT-V7212 P+
DLT-V7215 P+
-30 to +50 °C
Specification according to EN 60068-2-1/2
-30 to +60 °C
Specification according to EN 60068-2-1/2
-10 to +50 °C (ambient temperature)
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP65 and IP66 for:
DLT-V7210
DLT-V7212
DLT-V7212 P+
DLT-V7215 P+
Technical Data – Device
IP65 for:
DLT-V7210 K
DLT-V7210 KD
IP65 for:
DLT-V7210 K
DLT-V7210 KD
35 / 189