Page 2
® and RAM Mount™ are both trademarks of National Products Inc., 1205 S. Orr Street, Seattle, WA 98108. DLT-V6210 devices can be delivered with or without preinstalled software. For devices with preinstalled software observe the associated license agreements. We recognize all national and international trademarks and product names.
Do not repair or modify ............47 6.1.2. Installing the disconnecting device ........18 12.2. Regular checks and maintenance of the complete system ..47 6.1.3. Installation of DLT-V6210 on automotive objects ....19 12.3. Cleaning DLT-V6210 ............. 48 6.2. Preparations ................20 6.2.1.
Page 4
17. TECHNICAL CUSTOMER SUPPORT .........54 18. RETURN SHIPMENT FORM ............55 19. LIST OF FIGURES ...............56...
Pay attention to these manuals because they help avoid hazards, reduce repair costs and downtimes, and increase the reliability and service life of DLT-V6210. Keep the manuals for future use. Please contact DLoG GmbH if you require additional information or clarification. You can find the contact address in section Technical customer support.
CAUTION means that slight bodily injury can occur if this information is not observed. NOTICE: Physical damage Information about possible physical damage TIP / HINT Tips, hints for using the product Note about additional information in manuals Page 6 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
DLT-V6210 industrial PCs are data communication terminals for using in commercial environments (e.g. logistics, warehouse, manufacturing). Any other or additional use beyond this shall be deemed improper use. The user/operator of DLT-V6210 is solely responsible for any resulting damage. This also applies to any unauthorized modifications made to the device.
Find details on the Advantech-DLoG Internet homepage. LCD display The LCD display of DLT-V6210 series fulfills the highest quality standards and was inspected for pixel defects. However, due to technological reasons pixel defects can occur. This is not a malfunction; it is a part of the technical specifications.
2.4. Device identification/name plate The name plate is located on the rear side of DLT-V6210. It must remain legible at all times for the purpose of identifying the device. Do not damage the name plate or remove it from the device.
Unpacking Open the packaging carefully to prevent damaging the device inside. Save the packaging material (for possible forwarding transportation or return of DLT-V6210). Check the shipment for completeness and any possible damage. Always keep the supplied manuals and documents.
3.4. If return/repacking is necessary If DLT-V6210 is being returned to the manufacturer, a completely filled-out return package slip must be enclosed with every DLT-V6210. You can find this return package slip: at the end of this manual ...
4.2. Wi-Fi configuration (optional) Depending on the optional equipment and intended use of DLT-V6210, the settings and access data for Wi-Fi networks should be defined. 4.2.1. Radio wave emission hazards This information applies exclusively to DLT-V6210 devices that are equipped with wireless technology.
EIRP (Equivalent Isotropically Radiated Power), in the 2.4 GHz frequency band is set at 20 dBm (100 mw). Set the transmitting power of the Advantech-DLoG antenna so that the permitted EIRP limit value is complied with. Examples for worldwide:...
Only qualified skilled personnel may perform the mechanical installation work on DLT-V6210. If DLT-V6210 is incorrectly mounted, any DLoG GmbH warranty for this device will be void. 5.1.1. Correct installation location WARNING Risk of injury and damage due to improper deployment location.
Secure attachment Observe the following information about the mounting brackets: All brackets and mounting parts supplied by Advantech-DLoG are only intended to be used for attachment of the industrial PCs and the peripheral devices and may not be misused. ...
Damage and scratching of the touchscreen without transportation protective film. The front display of DLT-V6210 is protected during transportation by a transparent film. This film should remain on the front display during assembly to avoid damage to the front display surface.
Requirement: The installation location must be prepared (e.g. connection to the ignition, correct voltage, etc.) We recommend the following sequence for the mechanical and electrical installation: Determine a suitable mounting position for DLT-V6210. Secure device mounting at the targeted object (RAM Mount etc.). Connect external accessories to DLT-V6210.
WARNING Electrical shock due to lack of disconnecting device. DLT-V6210 industrial PCs are not equipped with disconnecting devices that are accessible from outside; they do not have switches. To enable the devices to be quickly disconnected from the power supply in emergency situations: ...
NOTICE: Physical damage Overvoltage on DLT-V6210 when charging the targeted object’s battery. DLT-V6210 must be disconnected from the battery while the battery is being charged. Or it must be ensured that the maximum permitted input voltage of DLT-V6210 is not exceeded. Advantech-DLoG DLT-V6210 Manual V1.00...
6.2. Preparations Lay out all cables which are ready to be connected to DLT-V6210. Select the appropriate slot on the connector panel of DLT-V6210. Check and test which order of the cables routing is the best to fit in the cable compartment.
DLT-V6210 may only be connected to a SELV circuit (Safety Extra Low Voltage). The SELV circuit is a secondary circuit that is designed to protect the voltage from exceeding the safe value when operation runs correctly or a single error occurs.
CPU. All cable shields and the housing are connected to shield ground. The chassis of some forklifts is on DC+. This means that DLT-V6210 chassis is also on DC+. Short circuits can arise when, for example, the ground potential of a peripheral device is on DC-.
(from inside to outside): Place “toothed washer“ first(internal). Then put the “Ring Tongue of the power supply cable” (flat side faces DLT-V6210 connector panel). Tightening the nut hand-tight. Advantech-DLoG DLT-V6210 Manual V1.00...
ATTENTION: Tighten the mounting screws sufficiently but on no account pinch or crush the cable. If you do, the cables may break or the cable insulation may get damaged. Fig. 6.4: Cable clip secured to the strain relief rail. Page 24 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
Make sure that peripherals with their own power supply are either switched on at the same time as DLT-V6210 or after the start of DLT-V6210. Otherwise, you must ensure that the backflow from the external device to DLT-V6210 cannot take place.
ATTENTION: Tighten the mounting screws sufficiently but on no account pinch or crush the cable. If you do, the cables may break or the cable insulation may get damaged. Fig. 6.7: COM cable on the connector panel; secured to the strain relief rail Page 26 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
The device is not completely sealed due to incorrect attachment of the cables and the cable cover. The protection class/category of DLT-V6210 is only ensured if the cable cover is properly installed. Improper installation can result in liquid penetrating into DLT-V6210 during operation. This will cause the risk of short-circuiting, corrosion and wear.
Time between switching off and on: 10 seconds After DLT-V6210 is shut down and switched off, it needs to wait at least 10 seconds until the device can react to a switch-on signal (<Power> button / ignition). Page 28 / 56 DLT-V6210 Manual V1.00...
Salty water on the PCT touchscreen can be interpreted as a "touch" and lead to malfunction. Multi-touch capability Depending on the installed operating system type, the PCT touchscreen of DLT-V6210 is multi-touch capable. This means it can detect two touch points simultaneously.
Blinking System thermal sensor faculty 0.5 sec. on / 0.5 sec. off Improper operation can cause damage and downtimes to DLT-V6210 and to the connected complete system. Operators of DLT-V6210 must be trained in the handling of the device. 7.4.
Page 31
The symbol of the fuse is FA. You will find the exact position on the sticker located on the connection plate of DLT-V6210. Advantech-DLoG DLT-V6210 Manual V1.00 Page 31 / 56...
“Ignition on” means that a control signal can be routed to this connection that matches the supply voltage level. The signal reference is DC-. 8.1.2. DC Power supply cable Fig. 8.2: DC Power supply cable with Phoenix Combicon, 3-pin Page 32 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
Page 33
WARNING Electrical shock or fire due to incorrect power supply cable. Only use original Advantech-DLoG power supply cables; these meet the specific requirements for low-temperature flexibility, UV resistance, oil resistance, etc. Fig. 8.3: DC connection cable pin assignment Advantech-DLoG DLT-V6210 Manual V1.00...
Service CFast under the antenna cap NOTICE: Physical damage Improper opening of the antenna cap can impair the function of entire DLT-V6210 system and in particular the Wi-Fi functionality. The antenna cap may only remain open during the service work.
CFast slot There is a CFast slot under the antenna cap. Exercise special care when removing and re-inserting CFast card. Only use CFast cards that have been approved by Advantech-DLoG. Advantech-DLoG DLT-V6210 Manual V1.00 Page 35 / 56...
Wi-Fi IEEE 802.11 ac/b/g/n Dual Band Diversity Number of antennas Type Omnidirectional antenna Directionality Optimized for the DLT-V6210 housing Frequency range Band 1: 2400 to 2485 MHz Band 2: 5150 to 5875 MHz Antenna gain Max. 5 dBi (without loss through the cable) Impedance 50 Ω...
Connector labeling N type or TNC N, jack, female, bottom RSMA plug for RSMA socket on the terminal Scope of delivery 3 m antenna cable Maximum transmitting 100 mW / 20 dBm power Advantech-DLoG DLT-V6210 Manual V1.00 Page 37 / 56...
9.3. Wi-Fi card (optional) Technical data Wi-Fi PCIe MiniCard Integrated in the device at the factory by Advantech-DLoG (internal PCIe MiniCard slot). Driver Generally, only drivers for Wi-Fi cards approved by Advantech-DLoG can be integrated into operating system images. Maximum radiated power 100 mW EIRP 9.4.
If connected to COM1, the scanner can be powered through the interface with a voltage of 5 V. Use only scanners that have been approved by Advantech-DLoG. Optional scanner brackets are available for DLT-V6210. Fig. 9.6: Example scanner bracket Advantech-DLoG DLT-V6210 Manual V1.00...
Fig. 9.7: Example touch stylus for PCT touchscreen 9.7. USB recovery stick (optional) The optional Advantech-DLoG recovery stick allows images to be backed up and restored onto DLT- V6210 when necessary (backup & recovery). Please contact your Advantech-DLoG sales representative if needed.
DC+ and DC- are directly connected to the power supply, the connection is of course run through fuses. The supply voltage is then linked to DLT-V6210’s ignition input via a switch, for example, the key switch of the ignition (also with a fuse).
10.3. Configuration The MDevice program is used for the configuration of the automatic shut down under MS Windows. The MDevice manual can be found online in the download center at www.advantech-dlog.com. Page 42 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
ESD Level 4 protected (according to EN 61000-4-2) 11.4. Network adapter (10/100/1000) DLT-V6210 is equipped with a 10/100/1000 Mbit network adapter with 10/100/1000 Mbit per second. This adapter can be accessed via the bottom of the device and offers an RJ45 connection jack.
DLT-V6210 is designed to support VESA mount standard. VESA-compatible drilling patterns for the RAM attachment and swivel joint brackets are located on the rear side of DLT-V6210. Dimensions without add-ons (in mm) : Need to use M6 screws and the length of thread should be between 8 to 10mm depending on the bracket thinkness to decide.
Page 46
Fig. 11.3: Position VESA drill holes of DLT-V6210 Support 75mm VESA dimension 75mm 75mm Page 46 / 56 DLT-V6210 Manual V1.00 Advantech-DLoG...
Check whether all connected cables are secured and the cable cover shuts tightly. WARNING Risk of accident due to unstable attachment of DLT-V6210. If the attachment of DLT-V6210 becomes loose and breaks during moving, this can lead to severe accidents. ...
Do not use any abrasive glass cleaner or cloths that could scratch the touchscreen. Cleaning the housing Ensure that DLT-V6210 is switched off and currentless. Clean the housing with a slightly dampened cloth. Do not use compressed air, a high-pressure cleaner or vacuum cleaner, as this can damage the surface.
You can use Reset to reset the software recalibration. Please contact DLoG GmbH if DLT-V6210 malfunctions. You can find the contact address in section Technical customer support. Advantech-DLoG DLT-V6210 Manual V1.00...
Reasonably foreseeable misuse 14.1. Observe the intended use DLT-V6210 industrial PCs are data communication terminals for using in commercial environments (e.g. logistics, warehouse, manufacturing). DLT-V6210 industrial PCs: are not approved for using in EX zones (potential explosion hazard). ...
Guidelines and certificates 15.1. FCC USA/CAN DLoG GmbH Germany indicated that the radiated emission of DLT-V6210 complies with the requirements set forth in Subpart B of Part 15 of the Federal Communication Commission (FCC) rules for Class A devices and the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus.
In France, Wi-Fi operation outdoors is only permitted in the 2454 – 2483.5 MHz range at max. 10 mW EIRP. 15.2. CE marking The devices of DLT-V6210 series were tested and fulfill the CE conformity requirements and carry the CE mark on the rear side of the device. Page 52 / 56 DLT-V6210 Manual V1.00...
End-of-life device disposal DLT-V6210 devices which are defective or ready for disposal which should be considered as special waste and can be recycled. They must not be disposed as general/domestic waste. Proper disposal in accordance with local regulations is required.
Page 55
[ ] Unit was already damaged on delivery (please enclose a copy of the delivery note) [ ] Delivery was incomplete Missing parts: [ ] The following error occurs when operating the unit: [ ] Separate error report is enclosed Advantech-DLoG DLT-V6210 Manual V1.00 Page 55 / 56...
Page 56
Fig. 9.7: Example touch stylus for PCT touchscreen ......................40 Fig. 11.1: RJ45 network port ............................... 44 Fig. 11.2: Dimensions of DLT-V6210 ..........................45 Fig. 11.3: Position VESA drill holes of DLT-V6210 ......................46 Page 56 / 56 DLT-V6210 Manual V1.00...
Need help?
Do you have a question about the DLT-V6210 and is the answer not in the manual?
Questions and answers