Chapter 23 Device HA
Second Option for Connecting the Bridge Interfaces on Two NXCs
Another option is to disable the bridge interfaces, connect the bridge interfaces,
activate device HA, and finally reactivate the bridge interfaces as shown in the
following example.
In this case the NXCs are already connected, but the bridge faces have not been
1
configured yet. Configure a disabled bridge interface on the master NXC but
disable it. Then set the bridge interface as a monitored interface, and activate
device HA.
Configure a corresponding disabled bridge interface on the backup NXC. Then set
2
the bridge interface as a monitored interface, and activate device HA.
370
Br0 {ge4, ge5}
Disabled
A
B
Br0 {ge4, ge5}
Disabled
A
B
Br0 {ge4, ge5}
Disabled
NXC5200 User's Guide