17
Fig. 2-1: Additional Phase and Earth Connection to the Base of the Palletizing Solution
Electrical Energy
Work on electrical equipment must only be carried out by qualified and authorized personnel.
l
Be aware of the possible residual energy after turning off an electrical device with large capacitive components. Wait the
l
appropriate amount of time before working on the device.
Secure the work area with temporary barriers and a warning note. Secure the main switch with a padlock to prevent unauthorized
l
switching on.
Use only isolated tools in the corresponding voltage level.
l
Use only fuses with specified cut-off current and appropriate dielectric strength.
l
Follow the 5 electrical engineering safety rules when working on electrical equipment:
1. Disconnect completely.
2. Secure against reconnection.
3. Make sure there is no voltage.
4. Perform grounding and short-circuiting.
5. Provide protection against adjacent live parts.
AX20/AX30 Palletizing Solution
CAUTION
Need help?
Do you have a question about the AX20 and is the answer not in the manual?