A-1-3 Special Functions - Omron NS10-TV Series Programming Manual

Ns-series programmable terminals
Hide thumbs Also See for NS10-TV Series:
Table of Contents

Advertisement

Appendices
NS Series Programming Manual
A-1-3
Special Functions
Setting
Buzzer sound
Key press sound
Maintenance function
Battery back up
Calendar clock
function
Device monitor
function
Video configuration
System
program
Transfer
transfer
function
Screen data
transfer
History save function
Printing function
PLC Data Trace
Device data transfer
Three types (continuous, short intermittent, long intermittent)
The type of buzzer sound is controlled at system memory bits $SB12 to $SB14.
Press the Command Button with the Buzzer stop function to stop the buzzer.
Alternatively, turn OFF system memory bits $SB12 to $SB14.
Settings under System Menu PT Operation Settings Screen/CX-Designer system
settings.
ON:
Buzzer sounds when $SB12 to $SB14 turn ON or when an error occurs.
When an error message or other x or ! dialog boxes are displayed.
OFF:
Buzzer does not sound.
ERR ON:
Buzzer sounds when an error occurs.
When an error message or other x or ! dialog boxes are displayed.
Settings under System Menu PT Operation Settings Screen/CX-Designer system
settings.
ON:
Input sound when functional object that receives PT input is pressed.
OFF: No input sound even when functional object that receives PT input is
pressed.
All settings status monitor function
The status of all settings can be checked from the System Menu Screen.
Communications test function
Communications can be tested by performing simple communications.
Data initialization
Data saved to the PT can be initialized from the System Menu.
Operation log/error log/alarm/event history/data log display
The record settings and data for all kinds of log data can be displayed.
Registered Screen test display function
Registered screens can be displayed and checked from the System Menu.
Hardware check
Hardware can be checked.
Operation log/error log/alarm/event history/data log back up
Calendar clock settings back up.
Battery life: 5 years (25°C)
At voltage drop: Orange RUN indicator
Current date and time display based on internal clock.
Display and settings using System Menu PT Operation Settings
Screen/CX-Designer Date/Time Object.
Maximum monthly margin at normal error temperature (25°C) is –39 to +65 seconds.
Can connect to CPM2A, CPM2C, CQM1, CQM1H, C200HS, C200HX/HG/HE-E/-ZE,
CS1G/CS1H, CS1G/CS1H-H, CJ1G, CJ1M, CJ2H, and CJ2M PLCs and switch
operation modes and display or change current word contents.
Image adjustments for Video Input Unit.
Vision Sensor Console outputs.
Downloads/uploads from CX-Designer (computer) or Memory Card.
Downloads/uploads from CX-Designer (computer) or Memory Card.
Saves operation log, error log, alarm, event history, or data log data to Memory Card.
Screen hardcopies
The printing method and compatible printers can be selected.
Reads the data from a CS/CJ-series PLC's trace memory and displays the data as a
time chart. This function can also set the data trace parameters.
Data can be transferred from the transfer source to the transfer destination under
specified conditions.
A-9
Appendix-1 Specifications
Specifications