Omron NS10-TV Series Programming Manual page 681

Ns-series programmable terminals
Hide thumbs Also See for NS10-TV Series:
Table of Contents

Advertisement

Appendices
NS Series Programming Manual
Supplement/
Enhancement
Ladder Monitor
Ver. 8.2
Supplement/
Enhancement
Device data transfer
SPMA communications
Batch format settings
Batch label settings
String Display and Input
objects
Analogue Meter improve-
ments
Password input keyboard
Time setting to move to
System Menu
Macro additions
Screen switch settings
Improvements in creation
methods for fixed objects
Data graphs for 128 points
Data blocks with 512 KB
CP1W-CIF41 compatibility
Ver. 8.3
Supplement/
Enhancement
Numeral Display & Input
String Display & Input
Ver. 8.4
Supplement/
Enhancement
Support for CJ2 data
structures
PictBridge support
improved
Modbus support improved
• The CJ2 CPU Units are now supported.
• A host can be connected to the PT for monitoring using EtherNet/IP.
Passwords can be set for changing present values and other operations.
Conditions can be set to transfer data from a source to a destination.
Applications running on a computer can access other devices through USB.
The following can be set to the same values for all labels:
• Address information
• List data
• Date display objects
A specified character string can be set for all of the labels for the following ob-
jects:
• Bit Lamp objects
• Bit Button objects
• Multi Function objects
An input method setting was added to move the cursor to in front of the charac-
ter string when the focus is set.
• The shape of the needle can be set to a straight line, arrow, or triangle arrow.
• The line width can be changed to up to 3 dots.
The user can specify the keyboard used to input a password.
The time before moving to the System Menu when two of the four corners of the
screen are pressed can be set.
Trigonometric and floating-point functions were added.
The default setting for the display sequence for screens now gives priority to
displaying fixed objects and frames first.
The method to create sectors and arcs has been improved.
The total number of addresses for constant logging was increased to 128 points
max.
The size of one data block was increased to 512 KB.
To connect to the CP1W-CIF41, select the check box to use the CP1W-CIF41 in
the Ethernet host settings under the CX-Designer communications settings.
Note: Connecting to the CP1E is not supported.
The input method can now be restricted to use only functional objects or bar-
codes, but not both.
The input method can now be restricted to use only functional objects or bar-
codes, but not both.
Data structures for CJ2 CPU Units can now be accessed.
The printing method and orientation can now be specified.
Bit devices can now be read.
A-38
Appendix-6 Additional NS Series Functions
Function
Function
Function
Function