Omron NS10-TV Series Programming Manual page 182

Ns-series programmable terminals
Hide thumbs Also See for NS10-TV Series:
Table of Contents

Advertisement

Section 2 NS Series Functions
NS Series Programming Manual
The following Dialog Box is displayed when Set Value is selected as the Action Type.
No.
Setting
1
Normal shape
2
Pressed
3
Same as value
Refer to Selecting Shape in 2-8 Common Functional Object Functions for information on how to set
fixed objects.
Label Tab Page
Set a label for each button. Refer to Labels in 2-8 Common Functional Object Functions for basic set-
tings information.
Frame Tab Page
Specify the colors and sizes of the button frame to change the shape or color when the button is de-
pressed or raised. Refer to Frames under 2-8 Common Functional Object Functions for details.
Maximum/Minimum Limits Tab Page
Set the maximum and minimum limits for the contents of the write address. The setting range for
maximum and minimum limits depends on the numeral types.
If the action type is Increment/decrement, the value can be returned to the maximum or minimum limit
if the limits are exceeded.
1
3
Click the Select Shape Button to set the button's normal shape.
Click the Select Shape Button to set the button's shape when it is pressed.
Sets the button shape that will be displayed when the contents of the write address
match the set value for Set Value button action types. When the values do not match,
the button shape will be that set as the normal shape.
2-133
Details
1
2
2-9 Buttons