Section 4 Using Functions
NS Series Programming Manual
Suggestions
Up to three pop-up screens can be created.
When multiple pop-up screens are to be opened at the same time, the display positions for the
screens can be specified so that they do not overlap.
The pop-up screen display position can be moved by pressing the Move Button. Move the screens if
there is overlap with the base screen that prevents the screens being viewed properly.
The displayed message can be switched to match the alarm by placing a Contents Display Object in
the pop-up screen and linking the alarm and contents switching.
Executing Set Expressions
Example:
To turn ON the Error lamp and sound a continuous buzzer when 1 or more monitored PLC
bits turns ON.
Error
1. Register the bits to be monitored under the alarm/event settings.
2. Register a macro with the following settings under the project properties.
Alarm/Event ON Timing: Execute (i.e., select)
Macro: $B0 = 1
$SB12 = 1
Alarm/Event OFF Timing: Execute (i.e., select)
Macro: $B0 = 0
$SB12 = 0
3. Set the lamp on the screen as shown below.
Address: $B0
Label:
Error
Suggestions
Macros can also be used to switch screens or display pop-up screens.
4-5
4-1 Application