Section 3 Using PTs
NS Series Programming Manual
Refreshing Graph Display at Specified Intervals
Graphs can be scrolled and the display refreshed at any time interval based on a specified time.
1. Select Set Address for updating display under the data log graph property setting, and then set an
address for specifying refreshing the display under Scroll Control Flag and an address where the
scroll time is stored under Address for Specifying Scroll Interval.
A
Scroll time address
contents: 10
Display refresh
address
A
ON
Scrolls 10 seconds worth
(when unit for time axis
scale is seconds)
3-16
3-5 Displaying Graphs