ADC FlexWave Prism System Reference Manual page 281

Host, remote and ems 5.1
Table of Contents

Advertisement

Table 11-1. EMS Alarm Descriptions and Corrective Actions (Cont.)
Alarm Name
HostSERFSynthAlarmFault
HostSysCardFanFault
HostUnderTempFault
RmtAcPowerSupplyFault
RmtACPowerSupplyMon1Fault
RmtDARTDCSupplyFault
RmtDARTDwnCon1SynLockFault
RmtDARTDwnCon2SynLockFault
RmtDARTFault
FlexWave Prism Host, Remote and EMS 5.1 System Reference
ADCP-77-073 • Issue 2 • 11/2009
Alarm
Severity
Level
Major
Major
Minor
,
Major
Major
Major
Major
Major
Description
Action
The configured clock
If clock source is
source is not
onboard and
providing an
persists, consult
acceptable signal
ADC, replace system
card. If clock source
is external, check
clock source,
connection
The Host fan is
Check fan for
spinning too slowly
mechanical problem.
If not fixable,
consult ADC, replace
fan
The temperature of
Check ambient
the Host is under its
conditions
lower operating limit
(-40 degrees
Fahrenheit )
A power supply is in
If persistent, consult
a failed state
ADC, may have to
replace one or more
power supply
located in the SeRF
Module
The on-board DC
If persistent (may be
voltages are out of
transient on
their valid ranges
startup), check If the
DC power switch to
the DART is in the
OFF position. If DC
power is ON, reset
set the RF Module. If
the alarm persists,
consult ADC, as you
may have to replace
RF Module
Lock state of the
If persistent, consult
first downconverter
ADC, replace RF
synthesizer
Module
Lock state of the
If persistent, consult
second
ADC, replace RF
downconverter
Module
synthesizer
Summary fault
If persistent, consult
status of DART
ADC, replace RF
upconvertor/
Module
downconverter and
DART FPGA status
© 2009 ADC Telecommunications, Inc.