button—When clicked, causes the Remote to reboot. This causes a
Reset Unit
Loss of Service until Remote has returned to normal operation. Typical down
time is two to four minutes. See
The use of the Reset Unit button causes Loss of Service and should not be used unless
other troubleshooting processes have been followed and did not fix the issue being
experienced at the Remote.
Decommission Unit
for that Remote and removes all corresponding alarms from the EMS alarm
summaries (see
FlexWave Prism Host, Remote and EMS 5.1 System Reference
ADCP-77-073 • Issue 2 • 11/2009
"Resetting a Remote Unit" on page
button—When clicked, deletes any configuration settings
"Decommissioning a Remote Unit" on page