Note 1. When the control mode is changed, the Inverter will revert to default settings. (The V/F con-
trol default setting is given above.)
Note 2. The default setting is 0.1 for V/f control with PG.
Note 3. The default setting is 2.00 s for Inverters with a capacity of 55 kW or more.
Note 4. The same capacity as the Inverter can be set by initializing this parameter.
Note 5. The setting range for Asian models is 0 to 300.0
Note 6. The setting range for Asian models is 0 to 1.

Tuning Parameters

Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
C1-01
0200
02
C1-02
0201
02
C1-03
0202
02
C1-04
0203
02
C1-05
0204
02
C1-06
0205
02
C1-07
0206
02
C1-08
0207
02
C1-09
0208
02
C1-10
0209
02
C1-11
020A
02
C2-01
020B
02
C2-02
020C
02
C2-03
020D
02
C2-04
020E
02
C3-01
020F
02
C3-02
0210
02
C3-03
0211
02
C3-04
0212
02
C3-05
0213
02
C4-01
0215
02
C4-02
0216
02
C4-03
0217
02
C4-04
0218
02
C4-05
0219
02
Name
At-
tribute
00
Acceleration time 1
01
Deceleration time 1
02
Acceleration time 2
03
Deceleration time 2
04
Acceleration time 3
05
Deceleration time 3
06
Acceleration time 4
07
Deceleration time 4
08
Deceleration Stop Time
09
Accel/decel time setting unit
0A
Accel/decel time switching frequency
0B
S-curve characteristic time at accelera-
tion start
0C
S-curve characteristic time at accelera-
tion end
0D
S-curve characteristic time at decelera-
tion start
0E
S-curve characteristic time at decelera-
tion end
0F
Slip compensation gain
10
Slip compensation primary delay time
11
Slip compensation limit
12
Slip compensation selection during
regeneration
13
Output voltage limit operation selection 0, 1
15
Torque compensation gain
16
Torque compensation primary delay
time constant
17
Starting torque value (forward) (See
note 4.)
18
Starting torque value (reverse) (See
note 4.)
19
Starting torque time constant (See note
4.)
Chapter 10
Setting
Setting
Default
range
unit
setting
0.0 to
0.1 s
10.0
6000.0
(Set with
(Set with
C1-10.)
C1-10.)
0, 1
1
1
0.0 to
0.1 Hz
0.0
400.0
0.00 to
0.01 s
0.20
2.50
0.00 to
0.01 s
0.20
2.50
0.00 to
0.01 s
0.20
2.50
0.00 to
0.01 s
0.00
2.50
0.0 to 2.5 0.1
0.0 (See
note 1.)
0 to
1 ms
2000
10000
(See
note 1.)
0 to 250
1%
200
0, 1
1
0
1
0
0.00 to
0.01
1.00
2.50
0 to
1 ms
200 (See
10000
note 1.)
0.0 to
0.1%
0.0
200.0
−200.0 to
0.1%
0.0
0.0
0 to 200
1 ms
10
Write
during
opera-
tion
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
Yes
No
No
No
No
Yes
No
No
No
No
10-53