Omron 3G3MV-PDRT2 User Manual page 294

Devicenet communications units
Table of Contents

Advertisement

Appendices
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
n013
010D
01
n014
010E
01
n015
010F
01
n016
0110
01
n017
0111
01
n018
0112
01
n019
0113
01
n020
0114
01
n021
0115
01
n022
0116
01
n023
0117
01
n024
0118
01
n025
0119
01
n026
011A
01
n027
011B
01
n028
011C
01
n029
011D
01
n030
011E
01
n031
011F
01
n032
0120
01
n033
0121
01
n034
0122
01
n035
0123
01
n036
0124
01
n037
0125
01
n038
0126
01
n039
0127
01
n040
0128
01
n041
0129
01
n042
012A
01
n043
012B
01
n044
012C
01
n045 to
---
---
n049
Note [ ] values indicate those for 400-V-class Inverters.
10-36
Name
At-
tribute
0D
Maximum voltage frequency (FA)
0E
Middle output frequency (FB)
0F
Middle output frequency voltage (VC)
10
Minimum output frequency (FMIN)
11
Minimum output frequency voltage
(VMIN)
12
Acceleration/Deceleration time setting
unit
13
Acceleration time 1
14
Deceleration time 1
15
Acceleration time 2
16
Deceleration time 2
17
S-shape acceleration/deceleration
characteristic
18
Frequency reference 1
19
Frequency reference 2
1A
Frequency reference 3
1B
Frequency reference 4
1C
Frequency reference 5
1D
Frequency reference 6
1E
Frequency reference 7
1F
Frequency reference 8
20
Inching frequency command
21
Upper frequency reference limit
22
Lower frequency reference limit
23
Frequency reference setting/display
unit selection
24
Rated motor current
25
Motor protection characteristics
26
Motor protective time setting
27
Cooling fan operation
28
Motor rotation direction selection
29
Acceleration time 3
2A
Deceleration time 3
2B
Acceleration time 4
2C
Deceleration time 4
---
Not used.
Chapter 10
Setting
Setting
Default
range
unit
setting
0.2 to
0.1 Hz
60.0
400.0
0.1 to
0.1 Hz
1.5
399.9
0.1 to
0.1 V
12.0
255.0
[24.0]
[0.1 to
510.0]
0.1 to
0.1 Hz
1.5
10.0
0.1 to
0.1 V
12.0
50.0
[24.0]
[0.1 to
100.0]
0, 1
1
0
0.0 to
0.1 s (set
10.0
6000
with
10.0
n018)
10.0
10.0
0 to 3
1
0
0.00 to
0.01 Hz
6.00
maxi-
(set with
0.00
mum fre-
n035)
quency
0.00
0.00
0.00
0.00
0.00
0.00
6.00
0 to 110
1%
100
0 to 110
1%
0
0 to 3999 1
0
0 to
0.1 A
Differs
150% of
with
the rated
capacity
output
current
0 to 2
1
0
1 to 60
1 min
8
0, 1
1
0
0, 1
1
0
0.0 to
0.1 s (set
10.0
6000
with
10.0
n018)
10.0
10.0
---
---
---
Write
during
opera-
tion
No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
---