Configurator Settings
Monitoring Methods
Using the Monitor Device Window
Click the General Tab in the Monitor Device Window.
• The voltage values are displayed in the Network Power Voltage, Network Power Voltage
(Peak), and Network Power Voltage (Bottom) fields.
• The ON/OFF status of the Network Power Voltage Drop Flag can be checked in the Unit status
report area. When the flag is ON, the Network Power Voltage Drop check box is selected.
Using the Maintenance Information Window
Click the General Tab in the Maintenance Information Window.
Note The differences from the Monitor Device Window are as follows:
• The voltage values shown in the Maintenance Information Window are when the maintenance
information was refreshed and not the present values.
• The Clear Buttons for the peak and bottom values are not included in the Maintenance Infor-
mation Window.
7-2-10 Unit Comment
Function
A user-defined name can be set for each Unit (up to 32 characters) and the names can be stored in
the Slaves.
Setting Methods
1.Click the General Tab in the Edit Device Parameters Window.
2.Set the user-defined name (name of the device driving the Inverter, etc.) in the Comment field.
General Tab Page in the
Monitor Device Window
The maximum and minimum values
can be cleared.
Unit status report area
Chapter 7
7-37