Omron 3G3MV-PDRT2 User Manual page 320

Devicenet communications units
Table of Contents

Advertisement

Appendices
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
L2-06
048A
04
L2-07
048B
04
L2-08
048C
04
L3-01
048F
04
L3-02
0490
04
L3-03
0491
04
L3-04
0492
04
L3-05
0493
04
L3-06
0494
04
L4-01
0499
04
L4-02
049A
04
L4-03
049B
04
L4-04
049C
04
L4-05
049D
04
L4-06
04C2
04
L5-01
049E
04
L5-02
049F
04
L6-01
04A1
04
L6-02
04A2
04
L6-03
04A3
04
L6-04
04A4
04
L6-05
04A5
04
L6-06
04A6
04
L7-01
04A7
04
L7-02
04A8
04
L7-03
04A9
04
L7-04
04AA
04
L8-01
04AD
04
L8-02
04AE
04
L8-03
04AF
04
L8-05
04B1
04
L8-07
04B3
04
L8-09
04B5
04
10-62
Name
At-
tribute
8A
KEB deceleration time
8B
Momentary recovery time
8C
Frequency reduction gain at KEB start
8F
Stall prevention selection during accel
90
Stall prevention level during accel
91
Stall prevention limit during accel
92
Stall prevention selection during decel
93
Stall prevention selection during run-
ning
94
Stall prevention level during running
99
Speed agreement detection level
9A
Speed agreement detection width
9B
Speed agreement detection level (+/−)
9C
Speed agreement detection width (+/−) 0.0 to
9D
Operation when frequency reference is
lost
C2
Frequency reference for loss of fre-
quency reference
9E
Number of auto restart attempts
9F
Auto restart operation selection
A1
Torque detection selection 1
A2
Torque detection level 1
A3
Torque detection time 1
A4
Torque detection selection 2
A5
Torque detection level 2
A6
Torque detection time 2
A7
Forward drive torque limit
A8
Reverse drive torque limit
A9
Forward regenerative torque limit
AA
Reverse regenerative torque limit
AD
Protect selection for internal DB resis-
tor
AE
Overheat pre-alarm level
AF
Operation selection after overheat pre-
alarm
B1
Input open-phase protection selection
B3
Output open-phase protection selec-
tion
B5
Ground protection selection
Chapter 10
Setting
Setting
Default
range
unit
setting
0.0 to
0.1 s
0.0
200.0
0.0 to
0.1 s
0.0 (See
25.5
note 2.)
0 to 300
1
100
0 to 2
1
1
0 to 200
1%
120 (See
note 3.)
0 to 100
1%
50
0 to 3
1
1
0 to 2
1
1
30 to 200 1%
120 (See
note 3.)
0.0 to
0.1 Hz
0.0
400.0
0.0 to
0.1 Hz
2.0
20.0
−400.0 to
0.1 Hz
0.0
400.0
0.1 Hz
2.0
20.0
0, 1
1
0
0.0 to
0.1%
80.0
100.0
0 to 10
1
0
0, 1
1
0
0 to 8
1
0
0 to 300
1%
150
0.0 to
0.1 s
0.1
10.0
0 to 8
1
0
0 to 300
1%
150
0.0 to
0.1 s
0.1
10.0
0 to 300
1%
200
0 to 300
1%
200
0 to 300
1%
200
0 to 300
1%
200
0, 1
1
0
50 to 130 1°C
Depends
on
capacity.
0 to 3
1
3
0, 1
1
1 (0)
(See
note 4.)
0, 1
1
0
0, 1
1
1
Write
during
opera-
tion
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No